T5 Rail LED Tube Light
ROLLING STOCK RETROFIT LIGHTING
POWERED BYLMX®TECHNOLOGY
RAILWAY

Rolling Stock T5 LED Tube Light

EN45545 and EN50155 compliant T5 LED tubes and LED lights for rolling stock, train, metro and tram interior retrofit — new-build and refurbishment.

PASSENGERFREIGHTLOCOMOTIVESDEPOT REFURBISHMENT

LED tube luminaire for new-build and retrofit rolling stock, meeting rail industry compliance standards including EN45545 and EN61373. Available in 24V/72V/110V DC and 230V AC, with flicker-free output via an integrated constant-current driver.

KEY SPECIFICATIONS
EFFICACY
Up to 160 lm/W
INPUT VOLTAGE
24V / 72V / 110V / 230V AC
IP RATING
IP40
LIFETIME
L90 > 54,300 hrs / L80 > 108,000 hrs
CCT
2700K–6500K
COMPLIANCE
EN45545 · EN61373 · EN50155

Published lumen and efficacy figures are based on the 4000K configuration. Performance may vary depending on CCT and configuration.

PRODUCT IN MOTION

ENGINEERED FOR DEMANDING ENVIRONMENTS

Cinematic build & light-quality showcase — precision optics, sealed housings and instant-start performance.

UP TO 160 lm/W
ROLLING STOCK LED RETROFIT

High-efficiency LED tube lighting for new-build and retrofit rolling stock, designed to meet rail industry compliance standards including EN45545 and EN50155.

RAIL STANDARDS & COMPLIANCE

The standards below are associated with this product and are identified in the LMX rolling stock technical documentation. Each standard addresses a distinct aspect of on-board railway performance — from the electrical environment and electromagnetic compatibility through to mechanical endurance and fire behaviour.

STANDARD
AREA
RELEVANCE TO ROLLING STOCK
EN 50155
ELECTRONIC EQUIPMENT FOR ROLLING STOCK
Defines the general requirements for electronic equipment used on railway vehicles, covering the electrical environment, supply voltage tolerances, operating temperature and service-life expectations. Establishes the baseline that on-board lighting control gear must meet.
EN 50121-3-2
EMC — ROLLING STOCK APPARATUS
Sets electromagnetic compatibility limits and immunity requirements for apparatus installed on rolling stock. Ensures the LED tube and its integrated driver neither emit interference that disrupts other on-board systems nor malfunction when exposed to the rail electromagnetic environment.
EN 61373
SHOCK & VIBRATION
Specifies the mechanical shock and vibration test categories for equipment mounted on railway vehicles. Validates that the luminaire and its connections withstand the dynamic loading encountered in service — acceleration, braking, track irregularities and coupling impacts.
EN 45545
FIRE BEHAVIOUR OF MATERIALS & COMPONENTS
Defines fire protection requirements for railway vehicles, covering material flammability, smoke density and toxicity. Relevant to the luminaire housing and diffuser materials used within passenger and crew areas of rolling stock.
EN 60081
TUBULAR FLUORESCENT LAMPS — DIMENSIONS
Specifies the dimensional and interchangeability requirements for linear fluorescent tubes. Ensures the LED replacement tube matches the established T5/T8 lamp envelope and lamp-holder geometry, enabling direct retrofit into existing lumininaire bodies.
EN 60529
INGRESS PROTECTION (IP)
Defines the IP classification system for enclosures. The rated IP level confirms the degree of protection against solid objects and water ingress relevant to the luminaire's intended installation location within the vehicle.
RIA 12
PROTECTION AGAINST TRANSIENTS
Addresses protection of traction and rolling stock electronic equipment against electrical transients and surges present on the vehicle supply. Relevant to the driver's tolerance of voltage spikes, switching transients and supply interruptions characteristic of the on-board electrical environment.

Standards listed reflect those identified in the LMX rolling stock technical documentation. Refer to the product datasheet for the full certification scope.

ROLLING STOCK LED LIGHTING GUIDE

Rail LED tube selection involves more than lamp length and wattage. Our guide explains the principal rolling-stock standards, electrical supply options, shock and vibration, EMC, fire performance and retrofit considerations for T5 and T8 rail LED tubes.

READ THE RAIL LIGHTING GUIDE

WHY LMX RAIL LED TUBES?

Why Use LMX Rail LED Tube Lights?

Rolling stock retrofit

LED tube lighting for new-build and retrofit passenger and freight rolling stock.

Retain existing luminaires

Designed to retrofit within suitable existing fluorescent luminaire housings.

Up to 160 lm/W

High-efficacy LED tube performance depending on configuration.

Multiple supply voltages

Versions available for 24V DC, 72V DC, 110V DC and 230V AC supply systems.

Rail compliance standards

EN45545, EN50155, EN61373 and EN50121-3-2 referenced in product documentation.

Project-specific support

LMX engineering can help configure the right tube for your rolling stock application.

APPLICATIONS

Designed for Rolling Stock Lighting

01

Passenger Vehicles

Interior and exterior lighting for passenger coaches and saloons.

02

Freight Wagons

Robust LED lighting for freight wagon and goods vehicle applications.

03

Locomotives & DMUs

Driver cab and compartment lighting for locomotives and diesel multiple units.

04

Depots & Refurbishment

Retrofit LED tubes for rolling stock refurbishment and depot maintenance programmes.

CERTIFICATIONS

EN45545
EN61373
EN50155
EN50121-3-2
EN60081
EN60529
EN62776
EN55015
EN61547
EN61000-3-2
EN61000-3-3
IEC62776
IEC62031
LVD
RoHS
IP40
CE
UKCA
PROPRIETARY ENGINEERING PLATFORM
POWERED BYLMX®TECHNOLOGY

Maximum useful light. Maximum efficiency.

Optimised optical, thermal and electrical design for high efficacy, long service life and reduced energy consumption.

KEY ENGINEERING FEATURES

Integrated constant-current driver with versions available for 24V DC, 72V DC, 110V DC and 230V AC supply systems
High-efficiency, flicker-free illumination with instant-start operation and efficacy up to 160 lm/W
Wide input-voltage tolerance with protection against reverse polarity, electrical transients, undervoltage and short supply interruptions
Adjustable 90° G5 end caps for accurate rotational alignment and controlled light distribution
Aluminium housing with frosted polycarbonate diffuser for effective thermal management and uniform 180° illumination

FULL SPECIFICATION TABLE

PRODUCT CODES
LX-DGA00-209-55-T / LX-DGA00-314-55-T / LX-DGA00-416-55-T / LX-DGA00-418-55-T / LX-DGA00-422-55-T / LX-DGA00-524-55-T
INPUT POWER
9W / 14W / 16W / 18W / 22W / 24W
EFFICIENCY
Up to 160 lm/W
LUMEN MAINTENANCE
L90 > 54,300 hrs / L80 > 108,000 hrs
BEAM ANGLE
180°
CRI
Ra >80 standard / Ra >90 available on request
COLOUR TEMPERATURE
3000K (Warm White) included — 2700K–6500K / OEM
INPUT VOLTAGE
DC24V / DC72V / DC110V / AC230V / 50–60Hz
VOLTAGE RANGE
16–36V / 50–100V / 75–154V / 165–275V
POWER FACTOR (PFC)
>0.9
FLICKER
Flicker Free
WEIGHT
132g / 176g / 225g / 250g
HOUSING MATERIAL
Aluminium body with polycarbonate frosted diffuser
CONNECTOR / LAMP HOLDER
G5 Lamp Holder
CONNECTOR ROTATION
90°
IP RATING
IP40
OPERATING TEMPERATURE
-25°C to 70°C
STORAGE TEMPERATURE
−30°C to +80°C
TUBE LENGTHS
563mm / 863mm / 1163mm / 1463mm × 22mm or OEM
DESIGNED SERVICE LIFE
15 Years
MTBF OF DRIVER
806,026 hrs
SWITCH CYCLES
100,000
WARRANTY
5 years
STANDARDS
EN 50155, EN 50121-3-2, EN 61373, EN 45545, EN 60081, EN 60529, EN 62776, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, IEC 62776, IEC 62031, EMC Directive Compliance, LVD, RoHS
PROJECT ENQUIRY

Specifying Rolling Stock LED Lighting?

Send us your vehicle type, supply voltage, tube length and required compliance standards. LMX can recommend the appropriate rail LED tube configuration for your retrofit or new-build project.

Need a custom specification?

Our engineering team can modify any parameter to suit your project requirements.