ATEX Hazardous Area LED Strip
ATEX certified LED strip for Zone 1/21 and 2/22 hazardous area lighting — supplied as a complete explosion-proof system with optional emergency backup.
ATEX certified LED strip for Zone 1/21 and 2/22 hazardous area installations. Configurable 24V/36V/48V AC or DC input delivering up to 1,000 lm/m with CRI ≥80, housed in an IP67 / IK10 injection-moulded silicone enclosure. Available in any project-selected white CCT plus amber, green and red for safety and signalling applications.
Output and power vary according to voltage and configuration. White CCT is project selectable; coloured variants are available for safety and signalling applications.
ATEX certified LED strip for gas and dust hazardous area installations, supplied as a complete explosion-proof lighting system with suitable power/driver enclosure and optional emergency backup.
VOLTAGE / OUTPUT CONFIGURATIONS
The ATEX LED strip is configurable across three documented voltage and output variants. Output and power vary according to voltage and configuration.
Output and power vary according to voltage and configuration.
ATEX / EX CERTIFICATION
LED Strip Ex Markings
Certification Standards
Certification Scope
ATEX documentation confirmed. The LED strip is certified for Zone 1/21 and Zone 2/22 hazardous areas per the Ex markings above.
ATEX & IECEx documentation available for the explosion-proof power/driver enclosure. The enclosure certification is separate from the LED strip certification.
IECEx certification applies to the explosion-proof enclosure, not the LED strip itself. White CCT is a product configuration capability and does not carry a separate certificate per Kelvin value.
COMPLETE ATEX LIGHTING SYSTEM
LMX can supply the ATEX LED strip as a complete hazardous-area lighting system, including the explosion-proof power/driver enclosure, low-voltage power supply and optional emergency backup. This provides a coordinated solution from the incoming mains supply through to the hazardous-area LED strip.
EXPLOSION-PROOF POWER SUPPLY & DRIVER BOX
The mains supply is connected to the explosion-proof enclosure containing the power supply/driver, which then provides the required low voltage to the ATEX LED strip. A Mean Well driver/power supply is housed within the explosion-proof enclosure.
The ATEX LED strip is supplied at low voltage from the explosion-proof enclosure. Mains voltage is not connected directly to the LED strip.
OPTIONAL EMERGENCY BACKUP
Optional Emergency Lighting
The explosion-proof power/driver enclosure can be supplied with an optional battery backup system, providing 12W emergency operation for approximately 1.5 hours. Contact LMX for project-specific emergency requirements.
APPLICATIONS
A specialist hazardous-area lighting system suitable for Zone 1/21 and Zone 2/22 applications, including locations where flammable gases, vapours or combustible dusts may be present.
ATEX HAZARDOUS AREA LIGHTING DESIGN
Choosing hazardous-area lighting depends on the classified zone, the gas or dust group and the temperature class — not on lux level alone. Our ATEX lighting guide explains zone classification, how to read the Ex markings, ATEX versus IECEx, system architecture and how to specify a compliant ATEX LED strip system for Zones 1, 2, 21 and 22.
READ THE ATEX LIGHTING GUIDEHAZARDOUS AREA CLASSIFICATION & EX PROTECTION
Hazardous areas are classified by the likelihood of an explosive atmosphere forming and by the type of flammable substance present — gas or combustible dust. The LMX ATEX LED strip is certified for Zone 1/21 and Zone 2/22 applications. The information below explains how to read the Ex markings and what the protection ratings mean.
Zone Classification
Area in which an explosive gas atmosphere is likely to occur in normal operation occasionally.
Area in which an explosive gas atmosphere is not likely to occur in normal operation and, if it does occur, will exist only for a short period.
Area in which combustible dust, as a cloud, is likely to occur in normal operation occasionally.
Area in which combustible dust, as a cloud, is not likely to occur in normal operation and, if it does occur, will exist only for a short period.
How to Read the Ex Marking
The ATEX LED strip carries two Ex markings — one for gas atmospheres and one for dust atmospheres. Each marking is built from a sequence of codes that together describe the certified protection.
Ingress & Impact Protection
Dust-tight (6) and protected against temporary immersion up to 1m depth (7). Confirms the sealed silicone enclosure excludes solid ingress and water entry in damp or wet hazardous locations.
Highest mechanical impact rating within the IK scale. Confirms the enclosure resists high-energy impacts without loss of ingress protection or structural integrity.
WHY LMX ATEX LED STRIP?
Why Use LMX ATEX Hazardous Area LED Strip?
ATEX certified for gas and combustible-dust hazardous area lighting.
Configurable 24V/36V/48V AC or DC delivering up to 1,000 lm/m at up to 83 lm/W.
Any white Kelvin value manufactured to specification; amber, green and red also available.
Supplied as a complete system with suitable explosion-proof power/driver enclosure.
Emergency backup system available for hazardous-area installations.
ATEX documentation for the strip; ATEX and IECEx documentation for the enclosure.
LMX engineering can configure a compliant hazardous-area lighting system.
The LED strip carries ATEX certification. The power/driver enclosure carries separate ATEX and IECEx documentation. The strip itself does not carry IECEx certification.
APPLICATIONS
Designed for Hazardous Area Lighting
Oil & Gas
Hazardous-area lighting for onshore and offshore oil and gas facilities.
Chemical & Pharmaceutical
Zone 1/2 and Zone 21/22 lighting for chemical and pharmaceutical processing environments.
Paint & Solvent Areas
Lighting for spray booths, solvent stores and flammable-material handling areas.
Grain & Dust Environments
Zone 21/22 lighting for grain handling, milling and combustible-dust environments.

ENGINEERED FOR DEMANDING ENVIRONMENTS
Cinematic build & light-quality showcase — precision optics, sealed housings and instant-start performance.
CERTIFICATIONS
KEY ENGINEERING FEATURES
FULL SPECIFICATION TABLE
Specifying a Hazardous Area Lighting Project?
Send us your zone classification, required lighting levels, area dimensions and supply requirements. LMX can configure a compliant ATEX LED strip system with suitable enclosure and optional emergency backup.
Need a custom specification?
Our engineering team can modify any parameter to suit your project requirements.